SIRO Air

SIRO Air Makeup Air Chimney

Supplies the Fireplace with Pre-Heated Combustion Air

Fire needs air to burn – the Siro Air chimney takes care of it on its own. Since there is no need to waste already heated indoor air for combustion, the room’s heat won't escape through the chimney. 

Comfortable,  
Draft-Free Indoor Air

The fireplace operates independently  
of other ventilation systems.

Solves Combustion Issues

Makes your fireplace more efficient and easier to use. 

Better Energy Efficiency

An internal air channel delivers pre-heated combustion air to the fireplace.

Exceptionally Safe Insulation Structure

Still 20% slimmer than competing products!

Air Supply Ensured

Clean combustion. Better energy efficiency. Smoke-free and draft-free indoor air. 

Unique Insulation Structure

 

Siro Air’s insulation design is the result of extensive product development. Unlike traditional chimneys, it features two insulation materials: a layer of heat-resistant silicate protects the mineral wool, helping it retain its top-notch insulating properties even in extreme temperatures. The air gap between the insulation layers further enhances safety.

 

 

Standard colours

Matte White

Siro mattavalkoinen

Glossy White

Siro kiiltävä valkoinen

Matte Light Grey

Siro matta vaalean harmaa

Crown Your Fireplace with Style

ECO-FRIENDLY POWDER COATING

 

Our comprehensive color selection offers a suitable option for every setting. Looking for something special?
Get in touch ›

Matte Dark Grey

Siro matta tumma harmaa

Matte Black

Siro mattamusta

Brushed Stainless Steel

Siro harjattu RST

TECHNICAL SPECIFICATIONS

Usage Fireplaces with a separate connection for combustion air (under 150 mm).
Application Fireplaces, stoves, masonry heaters, baking ovens, heating boilers, ventilation, outdoor kitchen grill, sauna stoves
Suitable fuels
Wood, pellets, gas, oil
Thermal insulation value ø 150mm
From inner flue to air duct: 0,452 m2K/W / out from air duct: 3 m2K/W
Thermal insulation value ø 175mm

From inner flue to air duct: 0,686 m2K/W / out from air duct: 2,63 m2K/W

Fire safety distance (mm) 40
Structure from inside out
Inner pipe, ceramic insulation, aluminium, air gap, aluminium, ceramic insulation, steel jacket
Flue pipe sizes (mm) 150, 175 (converted with an adapter to fit the fireplace outlet)
Outer diameters (mm)

265, 314

Temperature class
T600 
Wall penetrations
No
For enclosed structures
Yes
Lateral shifts
No
Product standard
EN 1856-1:2021
Type code
T600-N1-D/W-Vm-L50060-G40 / T600-N1-D/W-Vm-L20070-G40

designer's choice